Part Number Hot Search : 
AJ7100BF AJ60A REEL1 TPS79915 AJ60A DB201S TESN400A SMA13CA
Product Description
Full Text Search
 

To Download HIRP200 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 H HiTRON
2008/09/26
UNIVERSAL INPUT HARMONIC CORRECTION RESONANT AC-DC OPEN FRAME TRIPLE OUTPUT 200 WATTS INTERNAL SWITCHING POWER SUPPLIES HIRP200 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES 5" x 3" COMPACT SIZE IN 1U HEIGHT 5V STAND-BY & 12V FAN OUTPUTS RESONANT DESIGN CIRCUIT MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB. 22 & FCC CLASS A CE MARKING COMPLIANCE POWER DENSITY AS HIGH AS 9.95W/C.I.
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC. Input Connector: V-M connector. Input Frequency: 47-63Hz. Inrush Current: Typ. 11.4-11.7Arms@230Vac. Input Current: 1.95-2.16A @115Vac, 1.0-1.15A @230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR PUB. 22 & FCC Class A. Hold-up Time: Typ. 16-18mS @115Vac & 230Vac. Power Fail Signal: Installed. Remote ON/OFF: Installed. Power Factor & Harmonic Correction: Meet IEC 61000-3-2, PF typ.0.95@ full load. Leakage Current: Less than 0.75-0.79mA.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: V-H connectors. Output Wattage: Max. 200W. Line Regulation: Typ. 0.1%. Load Regulation: VO1 & VO3 typ. 1%. VO2 typ. 3.0%. Noise & Ripple: Typ. 1.0% peak to peak. OVP: Installed in VO1 & VO2 (Latch). Adjustability: Available at VO1. DC OK Signal: Installed. Overload Protection (OLP): Fully protected against output overload and short circuit. Typical 115-130% at 115Vac.Consult the factory for the special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 87-92%. Switching Frequency: 100-105K Hz. Circuit Topology: ZVS circuit. Transient Response: +12V and +24V voltage returns within 1mS following a 25% load change. +48V voltage returns within 1.75mS following a 25% load change. Safety Standard: UL 60950-1/EN 60950-1 Class I. Operating Temperature: 0 to +50C at full load with specified air flow. Storage Temperature: 0 to +85C. Temperature Coefficient: 0.05%/C. Cooling: 400LFM airflow is required to deliver the full power. 200W. Construction: PCB format. Power Density: 9.95 Watts / Cubic Inch.
Note: (1)Due to requests in market and advances in technology, specifications subject to change without notification. (2)All measurement are at nominal input, full load and +26C unless otherwise specifications.
OUTPUT VOLTAGE / CURRENT RATINGS CHART
TRIPLE OUTPUT(Under forced air cooling 400LFM)
MAIN VO1 @ MODEL NO. Max. HIRP200-T120IE HIRP200-T240IE HIRP200-T480IE 16.70A 8.30A 4.16A Typ 16.6A 8.3A 4.0A Volt. +12V +24V +48V Max. 1.0A 1.0A 1.0A Typ. 0.5A 0.5A 0.5A Volt. +12.0V +12.0V +12.0V Max. 0.1A 0.1A 0.1A Typ. 0.1A 0.1A 0.1A VO2 (Fan outputs)
2008/09/26
VO3 (Standby) Volt. +5V +5V +5V
Symbol: "" OVP built-in. "@" Adjustable.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 500.0g (17.6 Oz)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT ASSIGNMENT CNTR & PIN# AC-LINE P1-2 AC-NEUTRAL AC-GROUND P1-1 G +VO1 P2-2 DC-COM P2-1 +VO2 P3-5,6 TRIPLE OUTPUT +5VSB P3-3 DC-COM P3-4 POWER FAIL P3-1 REMOTE CONTROL P3-2
Remark: Short P3-2 and P3-3 to enable the PSU.